Tape the top of step flashing with 4 inch wide minimum self adhering modified bitumen roof tape.
Pto flashing at roof to wall detail.
Roof to wall flashing is bent at a 110.
Wall with self terminating parapro paraflex 531 liquid flashing.
Figure 2 steps 1 2 roof wall junction construction sequence.
Hold your cursor over the file name to view when a drawing was last updated.
Flashing joints are lapped 6 in the direction of water flow.
Wall flashing with coated metal edge.
The shorter vertical plane is attached to the upper floor wall under the building paper the lower plane sits on top of the underlayment and under the shingles.
Rain should run off the roof and into the gutter.
Paraguard expansion joint roof to roof with parasolo flashing.
Do not seal housewrap or building paper to step flashing.
At roof to wall intersections see figure 1.
Pdf t fw m2i highwall flashing with metal backing strip isometric view master detail.
Fit a self adhesive flexible flashing membrane over the junction.
Pdf t fw m1i tpo base wall flashing with coping isometric view master detail.
Because most roof flashing is required to extend up the wall a minimum of 4 and some a minimum of 5.
Wall base termination detail.
The detail drawings are grouped by details and can be downloaded below in dwg or pdf format.
It is designed to cover and protect roof to wall intersections from water infiltration.
Firestone has developed cad drawings of its tpo installation details to assist roofing professionals with the specification of firestone tpo roofing systems.
Roof leg and a 7 in.
The roof flashing is then placed up behind this through the wall z bar flashing on the outside of the vertical blocking backing material.
High wall flashing detail 10 wide sheets.
Cut and fold a section of the membrane across the roof underlay turn down.
Finally the housewrap can be laid up on the wall to cover the top of the kickout diverter and step flashings.
Turn the roof underlay up under adjacent wall underlay 1a and overlap the lower wall underlay 1b.
T fw m1 tpo base wall flashing with coping master detail.
The narrower step flashing just isn t wide enough to protect the intersection fully.
Most simply use a nominal 6 piece of lumber.
I recommend 12 in wide step flashings bent for a 5 in.
Paraguard expansion joint roof to wall with parasolo flashing.
The metal flashing is formed with a hook edge and cleated on 12 centers.
At the bottom of the roof water needs to be directed.
The flashing extends up the wall at least 4.
The flashing extends onto the roof a minimum of 2 inches 4 inches is preferable in more severe climate areas.
Step flashing protects the gap where roofs meet walls by weaving into the roof shingles.
Roof area divider curb type.
Pdf t fw m3i tpo self adhered base wall flashing with coping.